Diagnostic R/F Table

Inquire now

Diagnostic R/F Table

Click to enlarge image

 Brand Name DONGMUN

Description
 
This table is suitable for a wide range of Fluoroscopic and Radiographic examinations. Its compact size and sturdy construction makes it an ideal table for small hospitals and medical practices where space is a premium. The 2m long table top accommodates comfortably even the tallest patient and the 50cm vertical travel of the spot film device alloes examination of the largest patients without any discomfort. It tilting range from 90degrees vertical to -15degrees Trendelenburg makes the table an ideal solition for all types of study where gastro-intestinal contrast media are used. The long travel of the table top of +80 to -50cm combined with 50cm travel of the spot film device allows easy Fluoroscopic examination of all body parts without the need of repositioning the patient thus eliminating any

 

discomfort of traumatized patients.
 
An image intensifier of 6" or 9" can be fitted, or a fluoroscopic screen could be used instead. The image intensifier can be easily detached and parked in a convenient position to make the table easy to use for standard Radiographic examinations with overhead X-Ray tube. The internal bucky has a travel of 105cm to allow Radiographs of any part of the body. The image intensifier is supported by an overhead crane. A television chain with 12" or 14" monitor is attached to the image intensifier

 

 

Specifications

Parts
DM-RFT-5
Table tiling
type
motor driven
range
standard:+90°-15° option:+90°-20°
speed
90°/20sec., 50/60Hz
Tabletop sliding
type
motor driven
movement range
• horizontal:±50cm • upward[tilting position]:50cm
• lateral:±11cm[option]
speed
• 3.6cm/sec., 60Hz • 5cm/sec., 50Hz
Tabletop
material
Laminated 60mmT
focal distance
41cmH
filtration
less than 1.0mm AL. Eq. at 100KV
tabletop to film
6.5cm
Buckty device
type
solenoid reciprocating
grid
standard:40LPC 10:1,option:60LPC,70LPC
cassette range
13×18cm~35×43cm[5×7"~14×17"]
tarvel range
100cm
AEC mode
lon chamber[option]
Spot film device
parking
slide parking from left to right
locking
electromagnetic lock
longitudinal movement
60cm
transversal movement
±12cm
vertical movement
14cm~15cm
grid
standard:40LPC 10:1,option:60LPC,70LPC
AEC mode
lon chamber[option]
Compression cone
 
manual operation
Field collimation
under couch
motor driven
Image assembly
Image intensifier
12",9",6" selectable
 
TV Camera
CCD
 
Monitor
23",17",15",14" selectable
 
Trolley
four wheels, two shelves, 51cmL×44cmW×138cmH
Power requirement
 
220VAC,3KVA,50/60Hz, single phase
zWeight
net weight
650kg except image assembly
Dimensions
 
approx. 200cmL×72cmW×85cmH
Installation space
minimum
310cmL×158cmW×260cmH
 For the improvement, the design and specification is subject to change without a prior notice.

 

 

 

 

Features
 
• Sturdy and compact design resulting in smooth movements for patient's comfort
• Wide range of Fluoroscopic and Radiographic examinations.
• Exceptional range of travel of the table top and spot film device.
• Smooth motor driven tilting from +90degrees to -15degrees Trendelenburg with an automatic 0 degree stop.
• +80 to -50cm table top movement allows whole body examinations.
• The low absorption table top has an equivalent less than 1mm Al at 100kVp.
• Short distance between the table top and the bucky.(6.5cm)
• Fluoroscopic screen can be provided upon request.
• Front loaded spot film device.
• Fully motorized spot film device capable of film divisions
   -18 x 24cm into 4 spots acroos
   -24 x 30cm into 2 parts
   -35 x 35cm single shot
• The spot film device has an automatic lock out against accidental double exposure.
• Motorized under table collimator with automatic collimation to reduce the radiation does to the patient.
• Economically designed spot film device allows an easy and convenient operation
• Advanced design of the spot film device results in a smooth and fast operation

Related Keywords: Diagnostic R/F Table , Table